Insulated Novec1230 Fire Suppression System Without Residue For Data Center
Description
Perfluorohexanone is an important substitute for halon fire extinguishing agent, a compound of fluoroketones, and a colorless and odorless liquid at normal temperature and pressure.
The evaporation heat of perfluorohexanone is 1/25 of that of water, and the vapor pressure is 25 times of that of water. These properties make it easy to vaporize and exist in a gaseous state. It mainly relies on heat absorption to achieve fire extinguishing effect, and can put out Class A, B, C, and E fires. The principle of heat absorption and fire extinguishing is that PFH will form mixed gas with air, which has stronger heat storage capacity than air, which means that it can remove more heat during operation. Perfluorohexadone has the heat storage capacity of the existing commercial halon substitute.
The fire extinguishing design concentration of PFH is generally 4-6%, which is far lower than that of heptafluoropropane fire extinguishing agent (8-10%). The NOAEL concentration of perfluorohexadone is 10%, which is higher than the NOAEL concentration of heptafluoropropane fire extinguishing agent (9%), and the safety margin is relatively high.
Components
1. Mechanical parts: cylinder with container valve, frame for cylinder group, driving cylinder, frame for driving device, high pressure hose etc. It is mainly used for storing Novec1230 (FK 5-1-12) agent
2. Electrical parts: smoke detector, heat detector, bell etc.
3. Pipe fittings: conduit, connector, elbow, flange etc.
Working Principle
Here is the illustration of working principle to whole system.
Application
• Computer room, communication room, power distribution room, library, archives,
Museum, etc.
• Be used for electrical fire, liquid fire, solid fire, gas fire which can be cut off the gas
source before extinguishing occur, etc.
Advantages
There are a lot of advantages of the single zone Novec1230 fire suppression system compared to other fire suppression system.
1/ It is the single zone Novec1230 fire suppression system that can protect the largest volume among the Novec1230 fire suppression system. Only a single zone system can protect at most 3600 cubic meters.
2/ Using single zone Novec1230 fire suppression system can help saving money. Obviously, using several systems are more expensive than only using one.
3/ It helps saving place. Because it needs a separate room outside but next to the protected zone, so it won’t waste the places in the protected zone.
4/ The single cylinder has large capacity. It has 120l, 150l, and 180l capacity.
Packages
We always pack it with polyfoam firstly and then put it into a wooden case. Sometimes, in order to meet with customers or the safety requirement, we will make a pallet for the goods.