Non Corrosive Novec1230 Fire Suppression System Without Pollution For Computer Room
Description
Similar to heptafluoropropane fire extinguishing system, PFH fire extinguishing system is also divided into pipe network fire extinguishing system and prefabricated fire extinguishing system. The pipe network fire extinguishing system is mainly composed of fire extinguishing agent steel cylinder, drive cylinder, selector valve, collecting pipe, control pipeline, signal feedback device, leak detection device, pipeline, nozzle, etc. The fire extinguishing agent and high pressure nitrogen are stored in the steel cylinder. When the system starts to extinguish fire, the cylinder head valve and the selector valve are opened. The gas fire extinguishing agent is driven by high pressure gas through the pipeline, ejected from the nozzle, rapidly gasified, and extinguished through heat absorption and cooling. According to the number of protection zones, it can be divided into unit independent system and combined distribution system. Prefabricated fire extinguishing system is a fire extinguishing system with linkage control function, which is designed and assembled according to certain application conditions, such as extinguishing agent storage device and spraying components. Prefabricated fire extinguishing system, also known as cabinet gas fire extinguishing device, is composed of fire extinguishing agent cylinder, pipeline, nozzle, signal feedback component, leak detection component, drive component, etc.
Components
The pipe network model of Novec1230 fire suppression system consists of actually three parts: the pipe network part, the fire fighting equipment part and the electrical elements part. Here will explain the last two parts for customers.
The electrical elements is a set of detecting device, and it always plays a subsidiary role in each system. The electrical elements includes:several control panels, several manual buttons, some discharge indicator lights, some alarm bells, some sounder with light, some smoke detectors and heat detectors.
The main part of the system is fire fighting equipment. It is formed by several components: Novec1230 cylinders, a cylinder frame, nitrogen-pressure driving devices, a driving device frame, container valves, flexible hoses, liquid flow check valves, gas control pipes, gas flow check valves, manifolds, safety valves, selective valves, flanges, elbows and nozzles.
Working Principle
Here is the illustration of working principle to whole system.
Application
As its name says, the single zone pipe network Novec1230 fire suppression system is suitable for a single protected zone, whose volume should be less than 3600 cubic meters as well as proportion should be less than 800 square meters. Because of its property and principles of putting off fire, the single zone pipe network Novec1230 fire suppression system can be used to protect some large and also significant places, such as the followings:
- Computer rooms
- Telecommunication center
- Facilities underground
- Offshore oil extraction
- Library
- Data and paper archives
- Valuable article storage
- Power generator storage room
Advantages
It is very efficient for you to protect your possession. Since it is a system, it includes extinguishing device to put out fire in a short time. It means all agent will be discharged in less than 10 seconds. Then it will be flooding overall. In addition, it has time-delay mechanism. It is around 2 minutes. It means when a fire happens, there is enough time for people escaping the building. We have listed out two points for customer as reference.
1/ Flexible application in protection zones. As its structure and assembly of other useful components, it can concentrate one very big protection zone with the combination of multiple storage cylinders. Its coverage can be also very small with the system of a single cylinder.
2/ Combined distribution system. The most distinctive and flexible advantage of this system is combined distribution system, which will combine multiple rooms in one district or building but with different dimensions or in different floor. Meanwhile, it can reduce the cost based on the original by the least and safe utilization of fire extinguishing gas. Because of the adoption of selective valves that can guide the fire extinguishing gas into the room on fire, so it would be relatively smarter to monitor each room to avoid an accident. It is worthy to mention that the combined rooms should be less than 8 including 8 in accordance with our standard.