Specifications
Storage Pressure: 4.2MPa
Spraying Time: ≤10s
Filling Density: ≤1420kg/m3
Nominal Pressure: 5.3MPa
Test Pressure: 8.4MPa
Working Power: DC 24V 1.6A
Working Temperature: 0℃~50℃
Protected Zone Range:: Proportion: ≤800m² Volume: ≤3600m³
Starting Mode: Automatic, Electrical Manual, Mechanical Manual
Cylinder Volume: 40L、70L、100L、120L、150L、180L
Highlight:

Computer Room Fire Suppression System

,

FK 5-1-12 Fire Suppression System

Basic Infomation
Place of Origin: China
Brand Name: Air Giant
Certification: CAL,CMA,CNAS,ILAC-MRA,CCC
Model Number: QMP40/4.2, QMP70/4.2, QMP100/4.2, QMP120/4.2, QMP150/4.2, QMP180/4.2
Payment & Shipping Terms
Packaging Details: Plywood outer box with bubble bag or paper
Delivery Time: 10-15 working days
Payment Terms: L/C, D/P, T/T, Western Union, Paypal, Credit card
Supply Ability: 28000 sets per week
Product Description

Automatic FK 5-1-12 Fire Suppression System Without Pollution For Computer Room

 

Perfluorohexadone automatic fire extinguishing system, also known as Novec1230 / FK-5-1-12 automatic fire extinguishing system, is a gas fire extinguishing system based on perfluorocarbons, which is used to extinguish dangerous chemicals and other flammable and explosive objects.

The perfluorohexadone automatic fire extinguishing system uses the colorless and odorless perfluorocarbon Novec1230 / FK-5-1-12 as the fire extinguishing agent, which has the following characteristics:

 

1. Environmental protection: Novec1230 / FK-5-1-12 is a non-toxic, colorless, tasteless, non-corrosive, non-conductive and non-explosive fire extinguishing agent, which can protect equipment and environment from damage.

2. High efficiency: the PFH automatic fire extinguishing system can extinguish the fire quickly in a short time without any damage to the protected equipment.

3. High safety: Novec1230 / FK-5-1-12 fire extinguishing agent has high stability, is not easy to burn, and will not produce harmful substances. Therefore, the use of this fire extinguishing system can effectively ensure the safety of personnel and equipment.

4. Strong flexibility: PFH automatic fire extinguishing system can flexibly adapt to different fire extinguishing requirements, and is applicable to various sizes and types of places.

The working principle of the PFH automatic fire extinguishing system is that when a fire occurs, the system detector detects the fire source, and the controller will automatically open the vent valve to release the Novec1230 /FK-5-1-12 fire extinguishing agent from the pipe network and enter the fire extinguishing area to extinguish the fire. The fire extinguishing system is an ideal fire extinguishing device with simple operation, high automation and fast and effective fire extinguishing.

 

 

Working Principle

 

The working principle of the PFH automatic fire extinguishing system is that when a fire occurs, the system detector detects the fire source, and the controller will automatically open the vent valve to release the Novec1230 /FK-5-1-12 fire extinguishing agent from the pipe network and enter the fire extinguishing area to extinguish the fire. The fire extinguishing system is an ideal fire extinguishing device with simple operation, high automation and fast and effective fire extinguishing.

 

Here is the illustration of working principle to whole system.

 

Automatic FK 5-1-12 Fire Suppression System Without Pollution For Computer Room 0

 

Components

 

1. Mechanical parts: cylinder with container valve, frame for cylinder group, driving cylinder, frame for driving device, high pressure hose etc. It is mainly used for storing Novec1230 (FK 5-1-12) agent

2. Electrical parts: smoke detector, heat detector, bell etc.

3. Pipe fittings: conduit, connector, elbow, flange etc.

 

Automatic FK 5-1-12 Fire Suppression System Without Pollution For Computer Room 1

 

 

 

Application

 

• Computer room, communication room, power distribution room, library, archives,

Museum, etc.

 

• Be used for electrical fire, liquid fire, solid fire, gas fire which can be cut off the gas

source before extinguishing occur, etc.

 

Automatic FK 5-1-12 Fire Suppression System Without Pollution For Computer Room 2

 

Advantages

 

This system has a cylinder frame, whose shape is similar to a cabinet, so this system is called cabinet pipe network type Novec1230 (FK 5-1-12) fire suppression system. Besides, here is going to list out the advantages of this system.

 

1/ Place saving. This fire suppression system requires a separated room outside the protected zone, and will not occupy the places of the protected zone.

 

2/ Easy installation. A few components and an easy structure make the system install easily.

 

3/ Convenient transportation. Because of a few components and careful package, the transportation will be very convenient and safe.

 

 

Packages

 

We always pack it with polyfoam firstly and then put it into a wooden case. Sometimes, in order to meet with customers or the safety requirement, we will make a pallet for the goods.

 

Automatic FK 5-1-12 Fire Suppression System Without Pollution For Computer Room 3

Recommended Products
Get in touch with us
Contact Person : Missaya Lu
Tel : +86 188 1945 1181
Characters Remaining(20/3000)