UL HFC227ea fire suppression system without pollution for data center

1 set
MOQ
negotiation
Price
UL HFC227ea fire suppression system  without pollution for data center
Features Gallery Product Description Request A Quote
Features
Specifications
Model No.: AG227SP-16.6;AG227SP-28.3;AG227SP-40;AG227SP-49;AG227SP-52;AG227SP-50;AG227SP-60;AG227SP-70;AG227SP-80;AG227SP-90;AG227SP-100;AG227SP-120;AG227SP-150;AG227SP-103;AG227SP-147;AG227SP-153;AG227SP-160;AG227SP-170
Volumn(L): 16.6;28.3;40;49;52;50;60;70;80;90;100;103;120;147;150;153;160;170
Working Pressure: 2.5Mpa;4.2Mpa
Start Mode: Manual And Electromagnetic Start
Color: Red
System Type: Single Bottle And Single Area; Multi Bottle Single Zone And Multi Bottle Multi Zone
Basic Infomation
Place of Origin: China
Brand Name: Air Giant
Certification: UL(Urldorwri1er Laboratories Irlc);TPED;GB;DOT
Model Number: AG227SP-16.6;AG227SP-28.3;AG227SP-40;AG227SP-49;AG227SP-52;AG227SP-50;AG227SP-60;AG227SP-70;AG227SP-80;AG227SP-90;AG227SP-100;AG227SP-120;AG227SP-150;AG227SP-103;AG227SP-147;AG227SP-153;AG227SP-160;AG227SP-170
Payment & Shipping Terms
Packaging Details: Plywood outer box with bubble bag or paper
Delivery Time: 10-15 working days
Payment Terms: L/C, D/P, T/T, Western Union, Paypal, Credit card
Supply Ability: 28000 sets per week
Product Description

UL HFC227ea fire suppression system without pollution for data center
 
Description of UL FM200 Fire Suppression System
One of the most environmentally friendly systems is the HFC227EA Clean Agent Suppression System. By physically cooling the fire by eliminating the heat energy that interrupts the combustion cycle, it prevents the fire from being able to sustain itself. With the 227 system, UL certified

 

HFC227ea disinfectant gas provides safe fire protection for people, property and life stock. The most challenging aspect of the use of environmentally friendly suppression agents is that they can affect the ozone layer, but the HFC227EA system is completely echo friendly and is not a depleting ozone suppression agent, although sometimes the fumes produced by fighting fires can affect the ozone layer.
UL HFC227ea fire suppression system  without pollution for data center 0
 
Attributes of UL DOT series cylinders

Model No. Nominal pressure (bar) Nominal volume(L) Filling volume (kg)

Caliber

(mm)

Weight

(kg)

Min. Max.
AG227SP-25-49S 25 49 23.5 54.9 49 48
AG227SP-25-52S 25 52 25.0 58.2 49 56
AG227SP-25-62S 25 62 29.8 69.4 49 53
AG227SP-25-80S 25 80 38.4 89.6 49 65
AG227SP-25-103S 25 103 49.4 115.4 49 82
AG227SP-25-106S 25 106 50.9 118.7 49 84
AG227SP-25-147S 25 147 70.6 164.6 49 105
AG227SP-25-153S 25 153 73.4 171.4 49 108
AG227SP-25-16.7R 25 16.7 8.0 18.7 33 21
AG227SP-25-28.3R 25 28.3 13.6 31.7 33 29
AG227SP-25-49R 25 49 23.5 54.9 33 42
AG227SP-25-52R 25 52 25.0 58.2 33 50
AG227SP-25-62R 25 62 29.8 69.4 33 47

 
 
Features of UL FM200 Fire Suppression System

  • No residual after discharge
  • Electrical non conductive
  • 25Bar operating pressure
  • Suitable for flammable liquids and solids combustible materials
  • Optional: operating pressure of 42bar
  • Design concentration 7%
  • Suitable for occupied rooms
  • The full discharge period is 10 seconds

 
Application of UL FM200 Fire Suppression System

  • Bank vault
  • Laboratory
  • Rare Book Library
  • Electronic data room
  • Telecom switching room
  • Studio
  • Communication Center
  • Transformer room and distribution room
  • Electrical control room
  • Auxiliary power room
  • Combustible liquid storage room
  • Computer room


Packages of UL FM200 Fire Suppression System
We always pack it with polyfoam firstly and then put it into a wooden case. Sometimes, in order to meet with customers or the safety requirement, we will make a pallet for the goods.
UL HFC227ea fire suppression system  without pollution for data center 1