UL Certification Automatic FM200 Fire Suppression System With No Pollution For Archives
Description of UL FM200 Fire Suppression System
HFC-227ea is a clean gas fire extinguishing agent that does not contain particulate matter or oily residue. It is used on precision electronic equipment and has no residue or oily sediment. It can be removed from protected spaces through ventilation.
HFC-227ea has thermal and chemical stability, and its atmospheric retention time is about 36.5 years. It is not a substance that will persist for a long time after release.
Attributes of UL GB series cylinders
Model No. | Nominal pressure (bar) | Nominal volume(L) | Filling volume (kg) | Caliber (mm) | Weight (kg) | |
Min. | Max. | |||||
AG227SP-25-40M | 25 | 40 | 19.2 | 44.8 | 49 | 47 |
AG227SP-25-50M | 25 | 50 | 24.0 | 56.0 | 49 | 58 |
AG227SP-25-60M | 25 | 60 | 28.8 | 67.2 | 49 | 65 |
AG227SP-25-70M | 25 | 70 | 33.6 | 78.4 | 49 | 72 |
AG227SP-25-80M | 25 | 80 | 38.4 | 89.6 | 49 | 80 |
AG227SP-25-90M | 25 | 90 | 43.2 | 100.8 | 49 | 94 |
AG227SP-25-100M | 25 | 100 | 48.0 | 112.0 | 49 | 100 |
AG227SP-25-120M | 25 | 120 | 57.6 | 134.4 | 49 | 113 |
AG227SP-25-150M | 25 | 150 | 72.0 | 168.0 | 49 | 134 |
AG227SP-25-40K | 25 | 40 | 19.2 | 44.8 | 33 | 41 |
AG227SP-25-50K | 25 | 50 | 24.0 | 56.0 | 33 | 52 |
AG227SP-25-60K | 25 | 60 | 28.8 | 67.2 | 33 | 59 |
AG227SP-42-40M | 42 | 40 | 19.2 | 44.8 | 49 | 47 |
AG227SP-42-50M | 42 | 50 | 24.0 | 56.0 | 49 | 58 |
AG227SP-42-60M | 42 | 60 | 28.8 | 67.2 | 49 | 65 |
AG227SP-42-70M | 42 | 70 | 33.6 | 78.4 | 49 | 72 |
AG227SP-42-80M | 42 | 80 | 38.4 | 89.6 | 49 | 80 |
AG227SP-42-90M | 42 | 90 | 43.2 | 100.8 | 49 | 94 |
AG227SP-42-100M | 42 | 100 | 48.0 | 112.0 | 49 | 100 |
AG227SP-42-120M | 42 | 120 | 57.6 | 134.4 | 49 | 113 |
AG227SP-42-150M | 42 | 150 | 72.0 | 168.0 | 49 | 134 |
AG227SP-42-170M | 42 | 170 | 81.6 | 190.4 | 49 | 149 |
AG227SP-42-40K | 42 | 40 | 19.2 | 44.8 | 33 | 41 |
AG227SP-42-50K | 42 | 50 | 24.0 | 56.0 | 33 | 52 |
AG227SP-42-60K | 42 | 60 | 28.8 | 67.2 | 33 | 59 |
Features of UL FM200 Fire Suppression System
Application of UL FM200 Fire Suppression System
Fire suppression system HFC-227ea can be used in normal commercial and industrial settings. Typical areas that can be protected by this system include:
Packages of UL FM200 Fire Suppression System
We always pack it with polyfoam firstly and then put it into a wooden case. Sometimes, in order to meet with customers or the safety requirement, we will make a pallet for the goods.