Description of UL FM200 Fire Suppression System
One of the most environmentally friendly systems is the HFC227EA Clean Agent Suppression System. By physically cooling the fire by eliminating the heat energy that interrupts the combustion cycle, it prevents the fire from being able to sustain itself. With the 227 system, UL certified HFC227ea disinfectant gas provides safe fire protection for people, property and life stock. The most challenging aspect of the use of environmentally friendly suppression agents is that they can affect the ozone layer, but the HFC227EA system is completely echo friendly and is not a depleting ozone suppression agent, although sometimes the fumes produced by fighting fires can affect the ozone layer.
Attributes of UL TPED series cylinders
Model No. | Nominal pressure (bar) | Nominal volume(L) | Filling volume (kg) |
Caliber (mm) |
Weight (kg) |
|
Min. | Max. | |||||
AG227SP-25-40D | 25 | 40 | 19.2 | 44.8 | 49 | 42 |
AG227SP-25-50D | 25 | 50 | 24.0 | 56.0 | 49 | 48 |
AG227SP-25-60D | 25 | 60 | 28.8 | 67.2 | 49 | 53 |
AG227SP-25-70D | 25 | 70 | 33.6 | 78.4 | 49 | 59 |
AG227SP-25-80D | 25 | 80 | 38.4 | 89.6 | 49 | 64 |
AG227SP-25-90D | 25 | 90 | 43.2 | 100.8 | 49 | 73 |
AG227SP-25-100D | 25 | 100 | 48.0 | 112.0 | 49 | 78 |
AG227SP-25-120D | 25 | 120 | 57.6 | 134.4 | 49 | 89 |
AG227SP-25-150D | 25 | 150 | 72.0 | 168.0 | 49 | 105 |
AG227SP-25-160D | 25 | 160 | 76.8 | 179.2 | 49 | 104 |
AG227SP-25-16.6C | 25 | 16.6 | 8.0 | 18.6 | 33 | 21 |
AG227SP-25-28.3C | 25 | 28.3 | 13.6 | 31.7 | 33 | 29 |
AG227SP-25-40C | 25 | 40 | 19.2 | 44.8 | 33 | 37 |
AG227SP-25-50C | 25 | 50 | 24.0 | 56.0 | 33 | 42 |
AG227SP-25-60C | 25 | 60 | 28.8 | 67.2 | 33 | 47 |
AG227SP-42-40D | 42 | 40 | 19.2 | 44.8 | 49 | 42 |
AG227SP-42-50D | 42 | 50 | 24.0 | 56.0 | 49 | 48 |
AG227SP-42-60D | 42 | 60 | 28.8 | 67.2 | 49 | 53 |
AG227SP-42-70D | 42 | 70 | 33.6 | 78.4 | 49 | 59 |
AG227SP-42-80D | 42 | 80 | 38.4 | 89.6 | 49 | 64 |
AG227SP-42-90D | 42 | 90 | 43.2 | 100.8 | 49 | 73 |
AG227SP-42-100D | 42 | 100 | 48.0 | 112.0 | 49 | 78 |
AG227SP-42-120D | 42 | 120 | 57.6 | 134.4 | 49 | 89 |
AG227SP-42-150D | 42 | 150 | 72.0 | 168.0 | 49 | 105 |
AG227SP-42-160D | 42 | 160 | 76.8 | 179.2 | 49 | 104 |
AG227SP-42-170D | 42 | 170 | 81.6 | 190.4 | 49 | 108 |
AG227SP-42-16.6C | 42 | 16.6 | 8.0 | 18.6 | 33 | 21 |
AG227SP-42-28.3C | 42 | 28.3 | 13.6 | 31.7 | 33 | 29 |
AG227SP-42-40C | 42 | 40 | 19.2 | 44.8 | 33 | 37 |
AG227SP-42-50C | 42 | 50 | 24.0 | 56.0 | 33 | 42 |
AG227SP-42-60C | 42 | 60 | 28.8 | 67.2 | 33 | 47 |
Features of UL FM200 Fire Suppression System
In tests, the acute toxicity of HFC-227EA Agent was shown to be equivalent to that of Halon 1301. HFC-227EA Agent has been evaluated for cardiac sensitization through test protocols approved by the US EPA. The EPA’s SNAP Program classifies HFC-227EA Agent as acceptable for use as a total flooding agent in occupied spaces. Refer to the SNAP program rules for more information.
HFC-227EA Agent is clean, leaves no residue, thereby eliminating costly after-fire clean-up, and keeping expensive “down-time” to a minimum. Most materials such as steel, stainless steel, aluminum, brass, and other metals as well as plastics ,rubber and electronic components are unaffected by exposure to FM-200 Agent.
Application of UL FM200 Fire Suppression System
In usual commercial or industrial settings, HFC227ea may be applied for fire suppression systems. This system can be used to protect typical areas, such as: Bank strong room Libraries Bookstores Electronic data processing center Telephone switching studio Communication center Transformer and switchgear room Control room Test lab Inflammable liquid storage
Packages of UL FM200 Fire Suppression System
We always pack it with polyfoam firstly and then put it into a wooden case. Sometimes, in order to meet with customers or the safety requirement, we will make a pallet for the goods.