FM200 Gas System Without Pollution For Telecommunication Room

1 set
MOQ
negotiation
Price
FM200 Gas System Without Pollution For Telecommunication Room
Features Gallery Product Description Request A Quote
Features
Specifications
Storage Pressure: 4.2 MPa
Spraying Time: ≤10s
Filling Density: ≤950kg/m3
Nominal Pressure: 5.3MPa
Test Pressure: 8.4MPa
Working Power: DC 24V 1.6A
Working Temperature: 0℃~50℃
Protected Zone Range: Proportion: ≤800m² ; Volume: ≤3600m³
Starting Mode: Automatic, Electrical Manual, Mechanical Manual
Cylinder Volume: 40L、70L、100L、120L、150L、180L
Basic Infomation
Place of Origin: China
Brand Name: Air Giant
Certification: CAL,CMA,CNAS,ILAC-MRA,CCC
Model Number: QMP40/4.2, QMP70/4.2, QMP100/4.2, QMP120/4.2, QMP150/4.2, QMP180/4.2
Payment & Shipping Terms
Packaging Details: Plywood outer box with bubble bag or paper
Delivery Time: 10-15 working days
Payment Terms: L/C, D/P, T/T, Western Union, Paypal, Credit card
Supply Ability: 28000 sets per week
Product Description

FM200 Gas System Without Pollution For Telecommunication Room

 

FM200 (Heptafluoropropane, HFC-227ea) automatic fire extinguishing system is a gas fire, automatic control and fire detection is one of the modern intelligent automatic fire extinguishing system.

 

FM200 gas fire extinguishing system can be combined with physical and chemical reaction process rapidly and effectively eliminate heat, prevent the happening of the fire, the physical properties of FM200 performance in its molecule vaporizing stage can rapid cooling flame temperature; And the release of free radicals in the process of chemical reaction, will eventually stop burning a chain reaction.

 

 

Components

 

1. Mechanical parts: cylinder with container valve, frame for cylinder group, driving cylinder, frame for driving device, high pressure hose etc. It is mainly used for storing fm200 agent

2. Electrical parts: smoke detector, heat detector, bell etc.

3. Pipe fittings: conduit, connector, elbow, flange etc.

FM200 Gas System Without Pollution For Telecommunication Room 0

 

Working principle

 

Here is the illustration of working principle to whole system

 

FM200 Gas System Without Pollution For Telecommunication Room 1

 

 

Application

 

Electronic computer room, a data processing center, telecommunications facilities, process control, expensive medical equipment, industrial equipment, library, museum and art gallery, clean room, anechoic chamber, emergency power facilities, flammable liquid storage area, etc.

 

The place where the fire is easy to happen, like paint-spraying production line, aging-electrical equipment, rolling machine, printing machine, oil switch, oil immersed transformer, melt impregnating tank, tank, large generators, drying equipment, cement pro duction process of pulverized coal, and the ship's engine room, cargo hold, etc.

 

 

Advantages

 

It is very efficient for you to protect your possession. Since it is a system, it includes extinguishing device to put out fire in a short time. It means all agent will be discharged in less than 10 seconds. Then it will be flooding overall. In addition, it has time-delay mechanism. It is around 2 minutes. It means when a fire happens, there is enough time for people escaping the building. We have listed out two points for customer as reference.

 

1/ Flexible application in protection zones. As its structure and assembly of other useful components, it can concentrate one very big protection zone with the combination of multiple storage cylinders. Its coverage can be also very small with the system of a single cylinder.

 

2/ Combined distribution system. The most distinctive and flexible advantage of this system is combined distribution system, which will combine multiple rooms in one district or building but with different dimensions or in different floor. Meanwhile, it can reduce the cost based on the original by the least and safe utilization of fire extinguishing gas. Because of the adoption of selective valves that can guide the fire extinguishing gas into the room on fire, so it would be relatively smarter to monitor each room to avoid an accident. It is worthy to mention that the combined rooms should be less than 8 including 8 in accordance with our standard.

 