40L Enclosed Flooding Novec 1230 Fire Suppression System Without Pollution For Storage Room

1 set
MOQ
negotiation
Price
40L Enclosed Flooding Novec 1230 Fire Suppression System Without Pollution For Storage Room
Features Gallery Product Description Request A Quote
Features
Specifications
Storage Pressure: 4.2 MPa
Spraying Time: ≤10s
Filling Density: ≤1420kg/m3
Nominal Pressure: 5.3MPa
Test Pressure: 8.4MPa
Working Power: DC 24V 1.6A
Working Temperature: 0℃~50℃
Protected Zone Range:: Proportion: ≤800m² Volume: ≤3600m³
Starting Mode: Automatic, Electrical Manual, Mechanical Manual
Cylinder Volume: 40L、70L、100L、120L、150L、180L
Highlight:

40L Novec 1230 Fire Suppression System

,

Enclosed Flooding Novec 1230 Fire Suppression System

Basic Infomation
Place of Origin: China
Brand Name: Air Giant
Certification: CAL,CMA,CNAS,ILAC-MRA,CCC
Model Number: QMP40/4.2, QMP70/4.2, QMP100/4.2, QMP120/4.2, QMP150/4.2, QMP180/4.2
Payment & Shipping Terms
Packaging Details: Plywood outer box with bubble bag or paper
Delivery Time: 10-15 working days
Payment Terms: L/C, D/P, T/T, Western Union, Paypal, Credit card
Supply Ability: 28000 sets per week
Product Description

Enclosed Flooding Novec1230 Fire Suppression System Without Pollution For Storage Room

 

Perfluorohexanone is an important substitute for halon fire extinguishing agent, a compound of fluoroketones, and a colorless and odorless liquid at normal temperature and pressure.

 

The evaporation heat of perfluorohexanone is 1/25 of that of water, and the vapor pressure is 25 times of that of water. These properties make it easy to vaporize and exist in a gaseous state. It mainly relies on heat absorption to achieve fire extinguishing effect, and can put out Class A, B, C, and E fires. The principle of heat absorption and fire extinguishing is that PFH will form mixed gas with air, which has stronger heat storage capacity than air, which means that it can remove more heat during operation. Perfluorohexadone has the heat storage capacity of the existing commercial halon substitute.

 

The fire extinguishing design concentration of PFH is generally 4-6%, which is far lower than that of heptafluoropropane fire extinguishing agent (8-10%). The NOAEL concentration of perfluorohexadone is 10%, which is higher than the NOAEL concentration of heptafluoropropane fire extinguishing agent (9%), and the safety margin is relatively high.

 

 

Components

 

1. Mechanical parts: cylinder with container valve, frame for cylinder group, driving cylinder, frame for driving device, high pressure hose etc. It is mainly used for storing Novec1230 agent

2. Electrical parts: smoke detector, heat detector, bell etc.

3. Pipe fittings: conduit, connector, elbow, flange etc.

 

40L Enclosed Flooding Novec 1230 Fire Suppression System Without Pollution For Storage Room 0

 

 

Application

 

Electronic computer room, a data processing center, telecommunications facilities, process control, expensive medical equipment, industrial equipment, library, museum and art gallery, clean room, anechoic chamber, emergency power facilities, flammable liquid storage area, etc.

 

The place where the fire is easy to happen, like paint-spraying production line, aging-electrical equipment, rolling machine, printing machine, oil switch, oil immersed transformer, melt impregnating tank, tank, large generators, drying equipment, cement pro duction process of pulverized coal, and the ship's engine room, cargo hold, etc.

 

 

Advantages

 

It is very efficient for you to protect your possession. Since it is a system, it includes extinguishing device to put out fire in a short time. It means all agent will be discharged in less than 10 seconds. Then it will be flooding overall. In addition, it has time-delay mechanism. It is around 2 minutes. It means when a fire happens, there is enough time for people escaping the building. We have listed out two points for customer as reference.

 

1/ Flexible application in protection zones. As its structure and assembly of other useful components, it can concentrate one very big protection zone with the combination of multiple storage cylinders. Its coverage can be also very small with the system of a single cylinder.

 

2/ Combined distribution system. The most distinctive and flexible advantage of this system is combined distribution system, which will combine multiple rooms in one district or building but with different dimensions or in different floor. Meanwhile, it can reduce the cost based on the original by the least and safe utilization of fire extinguishing gas. Because of the adoption of selective valves that can guide the fire extinguishing gas into the room on fire, so it would be relatively smarter to monitor each room to avoid an accident. It is worthy to mention that the combined rooms should be less than 8 including 8 in accordance with our standard.

 

 

Packages

 

We always pack it with polyfoam firstly and then put it into a wooden case. Sometimes, in order to meet with customers or the safety requirement, we will make a pallet for the goods.

40L Enclosed Flooding Novec 1230 Fire Suppression System Without Pollution For Storage Room 1