Automatic 1.6Mpa HFC227ea Fire Extinguisher Without Residue For Anechoic Chamber
Hanging FM-200 fire extinguisher is a preset and independent fire extinguishing system. It is easily wall or ceiling mounted in the protected area to directly put out the fire, without pipe network distribution.
The thermal type hanging fire extinguisher is activated by glass bulb action. When temperature of the protected area rises to rated level, the glass bulb will be broken, and container valve will be opened to spray fire extinguishing agent. There is no need connection with alarm control system.
Parameters
No. | Specifications | Parameters |
1 | Tank size | 8Ltr, 10Ltr, 16Ltr, 20Ltr, 30Ltr |
2 | Device model | XQQW8/1.6, XQQW10/1.6, XQQW16/1.6, XQQW20/1.6, XQQW30/1.6 |
3 | Storage pressure | 1.6MPa |
4 | Maximum working pressure | 2.5MPa |
5 | Discharge time | ≤10s |
6 | Maximum filling Density | 1 kg/L |
7 | Activating Temperature | 68℃ |
8 | Ambient working Temperature | 0℃~50℃ |
Below data refers to regular temperature at 20 centigrade and atmospheric pressure at 1 bar. The max coverage would vary a little from the ambient temperature and pressure on the real condition.
Device model | Filling amount (kg) | Maximum working pressure(MPa) | Storage pressure (MPa) | Maximum coverage(m³) | Starting mode |
XQQW8/1.6 | 8 | 2.5 | 1.6 | 11.11 | temperature sensor Activating Temperature: 68℃ |
XQQW10/1.6 | 10 | 2.5 | 1.6 | 13.89 | |
XQQW16/1.6 | 16 | 2.5 | 1.6 | 22.22 | |
XQQW20/1.6 | 20 | 2.5 | 1.6 | 27.78 | |
XQQW30/1.6 | 30 | 2.5 | 1.6 | 41.67 |
Advantages
Though automatic FM200 fire extinguisher -- ceiling mounted style has two kinds of system, but their advantages are the same as followings:
1. Substantial consideration of little protection. Some areas, such as server rooms or electric rooms or the like would be very small, which require little fire extinguishing agent. Then, hanging type system can play its role.
2. Little occupation of space. As the protection zone is very small, so maybe there is no much space to place other machines or devices or objects. Then, the ceiling mounted style is designed with the small but efficient function of fire suppression and overall coverage to the whole room.
3. Convenient installation and transportation. Because of relative light and small figure, even one person can hold and fix it on the top of ceiling or wall. But additionally, the temperature-controlled model cannot be installed more than one piece in principle or practice.
Packages
We always pack it with polyfoam first and then put it into a wooden case. Sometimes, in order to meet with customers or the safety requirement, we will make a pallet for the goods.