Automatic HFC227ea Fire Extinguisher Without Pollution For Telecommunication Room
• Automatic suspension of HFC-227ea/FM200 fire firefighting equipment, assemble the container, container valve, nozzle, etc installed to the ceiling or the wall independently. Once fire occurs, the fire extinguisher will start automatically or manually.
• It's standard starting mode is temperature sensor and solenoid sensor.
• It is maily used in smaller room, does not occupy the the ground area.
• It works accurate and reliable, spray time is short, extinguishing fast.
• Construction, installation is simple, low engineering investment.
• Automatic HFC-227ea/FM200(Heptafluoropropane) fire extinguishing system is a set of fire extinguishing, automatic control and fire detection in one system which is the modern intelligent automatic fire extinguishing device.
Parameters
No. | Specifications | Parameters |
1 | Tank size | 8Ltr, 10Ltr, 16Ltr, 20Ltr, 30Ltr |
2 | Device model | XQQW8/1.6, XQQW10/1.6, XQQW16/1.6, XQQW20/1.6, XQQW30/1.6 |
3 | Storage pressure | 1.6MPa |
4 | Maximum working pressure | 2.5MPa |
5 | Discharge time | ≤10s |
6 | Maximum filling Density | 1 kg/L |
7 | Activating Temperature | 68℃ |
8 | Ambient working Temperature | 0℃~50℃ |
Below data refers to regular temperature at 20 centigrade and atmospheric pressure at 1 bar. The max coverage would vary a little from the ambient temperature and pressure on the real condition.
Device model | Filling amount (kg) | Maximum working pressure(MPa) | Storage pressure (MPa) | Maximum coverage(m³) | Starting mode |
XQQW8/1.6 | 8 | 2.5 | 1.6 | 11.11 | temperature sensor Activating Temperature: 68℃ |
XQQW10/1.6 | 10 | 2.5 | 1.6 | 13.89 | |
XQQW16/1.6 | 16 | 2.5 | 1.6 | 22.22 | |
XQQW20/1.6 | 20 | 2.5 | 1.6 | 27.78 | |
XQQW30/1.6 | 30 | 2.5 | 1.6 | 41.67 |
Advantages
Though automatic FM200 fire extinguisher -- ceiling mounted style has two kinds of system, but their advantages are the same as followings:
1. Substantial consideration of little protection. Some areas, such as server rooms or electric rooms or the like would be very small, which require little fire extinguishing agent. Then, hanging type system can play its role.
2. Little occupation of space. As the protection zone is very small, so maybe there is no much space to place other machines or devices or objects. Then, the ceiling mounted style is designed with the small but efficient function of fire suppression and overall coverage to the whole room.
3. Convenient installation and transportation. Because of relative light and small figure, even one person can hold and fix it on the top of ceiling or wall. But additionally, the temperature-controlled model cannot be installed more than one piece in principle or practice.
Packages
We always pack it with polyfoam first and then put it into a wooden case. Sometimes, in order to meet with customers or the safety requirement, we will make a pallet for the goods.